4310--Sources Sought Notice: Pressure Probes For Isolation Rooms New York Harbor, Manhattan Campus.
VETERANS AFFAIRS, DEPARTMENT OF.VETERANS AFFAIRS, DEPARTMENT OF.242-NETWORK CONTRACT OFFICE 02 (36C242)
About this archived opportunity
THIS REQUEST IS FOR SOURCES SOUGHT AND IS ISSUED SOLELY FOR INFORMATION AND PLANNING PURPOSES ONLY AND DOES NOT CONSTITUTE A SOLICITATION. THE SUBMISSION OF PRICING, CAPABILITIES FOR PLANNING PURPOSES, AND OTHER MARKET INFORMATION IS HIGHLY ENCOURAGED AND ALLOWED UNDER THIS RFQ IN ACCORDANCE WITH (IAW) FAR 15.201(e). DISCLAIMER This Sources Sought Notice is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this Sources Sought Notice is marked as proprietary and will be handled accordingly. IAW FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this Sources Sought Notice. SOURCES SOUGHT DESCRIPTION This is NOT a solicitation announcement. This is a Sources Sought Notice only. The purpose of this Sources Sought Notice is to gain knowledge of potential qualified sources and their size classification relative to NAICS code 339113 (size standard of 800 employees). Responses to this Sources Sought Notice will be used by the Government to make appropriate acquisition decisions. After review of the responses to this Sources Sought Notice, a solicitation announcement may be published. Responses to this sources sought synopsis are not considered adequate responses for a solicitation announcement. The Department of Veterans Affairs (VA), VISN 02 Network Contracting Office, is seeking sources that can provide Pressure Probes that at a minimum meets the following salient characteristics with a brand name or equal product for the Margaret Cochran Corbin VA Medical Center, Manhattan Campus: 1. Project Overview The Department of Veterans Affairs Manhattan VA Medical Center requires the procurement and installation of new or replacement pressure monitoring probes for three designated clinical departments: - Emergency Room (ER) Isolation Room - Sterile Processing Service (SPS) Storage Room - Surgical Intensive Care Unit (SICU) Isolation Room This work includes delivery, installation, testing, and commissioning of new sensors and replacement of faulty units. 2. Equipment to Be Provided - CCC 10080-DT-032 NIST Traceable Internal/External Temperature Sensor (Qty 5) - CCC 10071-032 NIST Traceable Internal Temperature + Remote Sensor (Qty 20) - CCC 10108-03-A NIST Traceable 24V 0.1 High Resolution Pressure Differential Monitor (Qty 10) - CCC 10113-032 NIST Traceable Solid Simulator Probe 6 (Qty 5) - CCC 10610-AN Analog Transmitter Installation Kit (Qty 40) 3. Scope of Work 3.1 Pre-Installation Activities - On-site walk-through with VA Engineering & Infection Control. - Inspect existing systems and determine necessary replacements or new installations. - Verify integration requirements and mounting/wiring needs. 3.2 Installation Activities - Install pressure differential probes and temperature sensors. - Replace faulty sensors as identified. - Install analog transmitter assemblies. - Ensure compliance with VA standards, ASHRAE 170, and ICRA protocols. 3.3 Calibration & Commissioning - Perform full NIST-traceable calibration. - Test alarms, BAS integration, and pressure performance. - Provide commissioning report to VA Engineering. 3.4 Documentation & Training - Provide calibration certificates. - Provide as-built documentation. - Provide warranty papers and brief staff training. 4. Contractor Responsibilities Contractor will provide all labor, materials, tools, safety equipment, and site cleanup while following infection control procedures. 5. VA Responsibilities VA will provide access, infection control coordination, and necessary power/network connectivity. 6. Project Deliverables - Completed installation in all units. - Operational and calibrated monitoring systems. - Certification package and training. 7. Warranty Manufacturer standard equipment warranty and minimum 1-year labor warranty. Line No. Quantity UOM Item Description 1 5 EA CCC 10080-DT-032 NIST Traceable Internal/External Tempera 2 20 EA CCC 10071-032 NIST Traceable Internal Temperature + Re 3 10 EA CCC 10108-03-A NIST Traceable 24B/0.1 High Resolution P Pressure Differential Monitor Lumity 4 5 EA CCC 10113-032 NIST Traceable Solid Simulator Probe-6 5 40 EA CCC 10610-AN Analog Transmitter Installation The information identified above is intended to be descriptive, not restrictive and to indicate the quality of the supplies/services that will be satisfactory. It is the responsibility of the interested source to demonstrate to the government that the interested parties can provide the supplies/services that fulfill the required specifications. If you are interested and are capable of providing the sought out supplies/services, please provide the requested information as well as the information indicated below. Response to this notice should include company name, address, point of contact, size of business pursuant to the following
Historical details
- Status
- Closed
- Deadline
- January 9, 2026
- First captured
- January 3, 2026
- Publisher reference
- 3dfb17847daf41f188f444bc4524bb79
This opportunity has closed
4310--Sources Sought Notice: Pressure Probes For Isolation Rooms New York Harbor, Manhattan Campus.
by VETERANS AFFAIRS, DEPARTMENT OF.VETERANS AFFAIRS, DEPARTMENT OF.242-NETWORK CONTRACT OFFICE 02 (36C242)
Get notified when similar opportunities open
We'll save this search and email you when new sources, sought, pressure opportunities are posted. Free.
Related opportunities
- SMD_PS_RFP_521120_ Outreach Services Inside Residential BuildingsNew York City Housing AuthorityCloses in 9 days
- Request For Proposals For On-Call Marine Repair ServicesHudson River Park TrustCloses in 5 days
- FOR THE PROVISION OF PROFESSIONAL BRIDGE INSPECTION, LOAD RATING, & MAINTENANCENew YorkCloses in 10 days
- Port InfrastructureNYSERDACloses Nov 2027
- CUNY Brooklyn College LaGuardia Library IT Server HVAC Upgrade and HAZMAT AbatementDormitory Authority of the State of New YorkCloses in 23 days
- IFB 26-036 Hazardous Waste RemovalMental Health, NYS Office ofCloses in 4 days