WWYK210129 Repair Facility HVAC Control System, B2122
DEPT OF DEFENSE
About this archived opportunity
WWYK210129 Tinker AFB (TAFB) Oklahoma is soliciting a source�s sought to see if there are any contractors capable of completing the requirements found in the attached project Statement of Work (SOW) and drawings; TAFB Honeywell partner will be required at a minimum for SOW 4.2.1.3 . If respondent is only capable of being a General Contractor, please provide your average percentage for Design, G&A, Overhead, Profit and Bonds; as well as a statement that Tinker Honeywell would be a required sub-contractor and an estimated percentage of how much of the required work would be required to be performed with Tinker Honeywell as your prime sub-contractor. The work to be performed under the terms of this contract consists of furnishing all design/engineering services, materials, labor, plant, tools, transportation, equipment, testing services, quality control and incidentals required to accomplish the repair/replacement/addition of the HVAC controls and change to a BACNet system in B2122 at Tinker Air Force Base (AFB), Oklahoma (reference the project drawings for additional location information). The Contractor shall perform a site investigation to verify existing conditions. If necessary, additional as-built drawings are available from 72 ABW/CE - Engineering Support, located in B400. The Contractor shall be responsible for identifying the necessary logistical, architectural, and structural work elements required to perform the work as described herein. Assemblies, framework, fixtures, or apparatus not readily identified on the project drawings or this Statement of Work (SOW) shall be provided by the Contractor as required for a complete, fully operating, and functioning system or systems ready for use by the Government. Information such as floor plan layouts and dimensions; structural, mechanical, and electrical data; and location of underground utilities provided by the Government for existing and new construction are based on available as-built documentation, field observation, and equipment selected as design basis by the Government. This information is to be considered approximate and shall be field verified by the Contractor.
Historical details
- Status
- Closed
- Deadline
- January 20, 2026
- First captured
- January 11, 2026
- Publisher reference
- 419483ae07bc46f7a7f8063372e0f78e
Eligibility: No Set aside used. NONE
This opportunity has closed
WWYK210129 Repair Facility HVAC Control System, B2122
by DEPT OF DEFENSE
Get notified when similar opportunities open
We'll save this search and email you when new repair, facility, control opportunities are posted. Free.
Related opportunities
- WWYK150185 - REPAIR ROADWAYS, PARKING AT MUNITIONS AREA & WWYK190230 - REPAIR ARNOLD AVE BETWEEN H AVE AND M AVEDEPT OF DEFENSECloses in 5 days
- WWYK150185 - REPAIR ROADWAYS, PARKING AT MUNITIONS AREA & WWYK190230 - REPAIR ARNOLD AVE BETWEEN H AVE AND M AVEDEPT OF DEFENSECloses in 5 days
- WWYK150185 - REPAIR ROADWAYS, PARKING AT MUNITIONS AREA & WWYK190230 - REPAIR ARNOLD AVE BETWEEN H AVE AND M AVEDEPT OF DEFENSECloses in 5 days
- WWYK250096 - Repair Stormwater Spill Gate 11 StructureDEPT OF DEFENSECloses tomorrow
- WWYK250096 - Repair Stormwater Spill Gate 11 StructureDEPT OF DEFENSECloses tomorrow
- B522 HVAC, B414 DEMODEPT OF DEFENSECloses in 11 days