NIST Boulder Building 2 1330 Fume Hood Replacement
COMMERCE, DEPARTMENT OF
About this archived opportunity
The project consists of construction services to remove and replace an existing laboratory tabletop fume hood and associated rooftop exhaust fan located in Building 2, Room 1330 at the NIST Boulder Campus. Work will include demolition and replacement of existing countertops, sink, base cabinetry, plumbing connections, and associated architectural finishes. Mechanical work includes removal of the existing fume hood, ductwork, and rooftop exhaust fan and installation of a new walk-in fume hood, hazardous exhaust fan, exhaust stack, and duct connections. Electrical work includes removal and installation of circuits serving the fume hood and exhaust fan, installation of cable tray and dedicated receptacles for laboratory equipment, reconnection of lightning protection systems, and bonding of the hood and exhaust system. Plumbing work includes reconnecting existing piping to a new sink and eyewash station. Fire alarm work includes installation of a supervised fume hood panic alarm system connected to the building fire alarm panel. The contractor will also provide structural design and installation of exhaust fan stack supports, perform ASHRAE 110 performance testing of the hood and exhaust system, and coordinate construction activities with NIST personnel. Important Dates: List of Individuals due for Site Visit: Monday, June 15, 2026 Site Visit: Wednesday, June 17, 2026 @ 2:30 PM outside Building 2 Questions Due: Monday, June 22, 2026 Proposals Due: Wednesday, July 1, 2026 Please see Instructions to Offerors on Page 111 of the solicitation for details around registering for the site visit.
Historical details
- Status
- Closed
- Deadline
- July 1, 2026
- First captured
- June 10, 2026
- Publisher reference
- d29fa54458294b82a99ea13ae493da10
Eligibility: Total Small Business Set-Aside (FAR 19.5). SBA
This opportunity has closed
NIST Boulder Building 2 1330 Fume Hood Replacement
by COMMERCE, DEPARTMENT OF
Get notified when similar opportunities open
We'll save this search and email you when new boulder, building, fume opportunities are posted. Free.
Related opportunities
- Steam Tunnel Ventilation ReplacementCOMMERCE, DEPARTMENT OFCloses in 10 days
- B1806 Repair Control Tower HVACDEPT OF DEFENSECloses in 22 days
- Steam Tunnel Ventilation ReplacementCOMMERCE, DEPARTMENT OFCloses in 10 days
- IRV Exhaust and Vacuum Pump ReplacementHEALTH AND HUMAN SERVICES, DEPARTMENT OFCloses in 19 days
- B522 HVAC, B414 DEMODEPT OF DEFENSECloses in 4 days