ULTRASOUND
VETERANS AFFAIRS, DEPARTMENT OF
This opportunity closed July 21, 2026. 5 similar opportunities are open right now.
Similar opportunities open now
- 6515--Ophthalmic A/B-Scan–Pachymeter Ultrasound *BRAND NAME OR EQUAL*Same funderOpenVETERANS AFFAIRS, DEPARTMENT OFNo deadline listed
- 6540--NX EQ Scanning Systems Ultrasonic Ophthalmic AB Scan (VA-27-00003110)Same funderOpenVETERANS AFFAIRS, DEPARTMENT OFNo deadline listed
- 6515--OPHTHALMIC ULTRASOUND SYSTEM AND ACCESSORIESOpenVETERANS AFFAIRS, DEPARTMENT OF.VETERANS AFFAIRS, DEPARTMENT OF.260-NETWORK CONTRACT OFFICE 20 (36C260)Closes in 2 days
- 6910--Ultrasound SimulatorSame funderOpenVETERANS AFFAIRS, DEPARTMENT OFNo deadline listed
- 6515--Ultrasound Therapy System | VA San DiegoSame funderOpenVETERANS AFFAIRS, DEPARTMENT OFNo deadline listed
About this archived opportunity
ELLEX ABSOLU S ULTRASOUND CONSOLE WITH A-STD PROBE (P/N PCBX0037S1S) QTY:1 ELLEX BIOMETRY A-SCAN PROBE FOR ABSOLU Ground plate w/o filter QTY:2 ELLEX 15 MHz B PROBE FOR ABSOLU/ABSOLU S QTY:2 50 MHz LINEAR HIGH-RESOLUTION PROBE FOR ABSOLU/ABSOLU S SYSTEMS ONLY QTY:1 STANDARDIZED A PROBE (PROBE ONLY) FOR ABSOLU S MODULES ONLY QTY:5 ELLEX BOX OF CLEARSCANS QTY:1 ELLEX DICOM SOFTWARE FOR ABSOLU ULTRASOUND QTY:1 ELLEX WIRELESS 9 FUNCTION FOOTSWITCH FOR ABSOLU/ABSOLU S QTY:1 ELLEX ULTRASOUND CART FOR ABSOLU & COMPACT TOUCH 2 QTY:1 ELLEX ULTRASOUND CLINICAL APPLICATIONS TRAINING QTY:1 Salient Characteristics Brand Name or Equal: A-scan Biometry: to verify measurements of the length of the eye (axial length) -Immersion A-scan -Direct contact A-scan -QTY Two (2) Biometry A-scan transducers -Auto Axial length average and standard deviation calculations -IOL Formulas -Lens Database -measurement tools B-scan 15 MHz B-scan probe -Qty Two (2) Biometry B-scan transducers UBM -QTY One (1) UBM Transducer -QTY Ten (10) single-use sterile UBM-probe cover devices -QTY Six (6) 8-MHz A-scan diagnostic transducers allows for: diagnosis of tumor lesions, diagnosis of retinal vitreous membrane detachment and diagnosis of Graves disease -probe positioning feedback/visualization -Static and dynamic image capture and storage -Image Annotation -pachymetry probe self-check/auto calibration -DICOM networking, compatibility to send to Ziess Forum -Footswitch -height-adjustable cart with keyboard tray -1-day on-site Clinical Applications training to identify sight threatening retinal lesions, such as ocular tumors measurements critical in determining what power lens implant to place in the eye after cataract surgery -Sulcus-to-Sulcus measurements -corneal thickness measurements -IOP correction formulas VA Networked Medical Device risk assessment documents: VA Directive 6550 Ports, Protocols, and Security spreadsheet Inventory List MDS2 Network Topology Diagram Software Bill of Materials A Letter of support is required if there is any vendor proprietary firmware, customized OS, or COTS Devices (i.e. NAS, Firewall, switch, HW load balancer, etc.)
Historical details
- Status
- Closed
- Deadline
- July 21, 2026
- First captured
- July 8, 2026
- Publisher reference
- 406eb5b940af4a8fac36cebf03901f4f
Eligibility: Service-Disabled Veteran-Owned Small Business Set Aside. SDVOSBC
Free. One email, sent if this program reopens or a close match to it opens. We watch for 12 months, then stop. No list.